• Optima TC120 Heated Circulating Bath

    The Grant TC120 series of digital heating circulating baths for general applications requiring precision temperature control in the range of -15°C to 120°C. The TC120 heating circulator can be used in combination with any Grant stainless steel or plastic tank or with a T-Clamp for independent use of virtually any vertical sided tank.

    • Cooling/heating range -15°C to 120°C
    • Stability ±0.05ºC / Uniformity  ±0.1ºC
    • Tank options 5L to 38L
    • Simple, intuitive user interface: dial and two function buttons
    • 3 programmable temperature presets
    • Clear, bright 4 digit LED display
    • Low level protection and adjustable over temperature cut out
    • Countdown timer with audible alarm

    Applications

    • Clinical, Microbiology and Pathology labs – media tempering, thawing and incubating samples
    • University research – temperature control of spectrophotometers and refractometers and jacketed vessells
    • Industrial labs – temperature probe calibration, water analysis, QC testing product, petrochemical testing, material testing, milk sample testing

    Specifications

    Dimensions (h x d x w)333 x 172 x 141mm
    Stability (DIN 12876) @70ºC0.05±ºC
    Uniformity (DIN 12876) @70ºC0.1±ºC
    Setting resolution0.1ºC
    Display4 digit LED
    Timer function1 minutes to 99 hours 59 minutes
    No. of temperature presets3
    Re-calibration points2
    Socket for external probe (TXPEP, TXSEP)
    Communications interface
    Programmable
    Relays
    Safety – over temperatureAdjustable cut-out
    Fluid level – float
    Language options
    Alarms (can be configured to switch a relay)High (no relay)
    Heater power – 230V1290W
    Heater power – 120V1440W1440W
    Electrical power – 230V1400 (50-60Hz)
    Electrical power – 120V1500 (50-60Hz)
    Height above tank rim20mm
    Depth below tank rim135mm
    Maximum pressure (water)210mbar
    Maximum flow (water)16L/min
    Pump connector 6mm boreFits 9mm inner diameter tubing
    Pump connector 11mm boreFits 15mm inner diameter tubing
    Weight2.3kg

    .

    Downloads

     Internet Explorer browser is not supported

    Use an alternative browser to access PDFs for view and download.

    Product Manuals:

    Technical Datasheets:

    Further Information:

     

    Products in range

    Model Number

    Unit Size

    TC120-ST55 L
    TC120-ST1212 L
    TC120-ST1818 L
    TC120-ST2626 L
    TC120-ST3838 L
    TC120-P55 L
    TC120-P1212 L
    TC120-P1818 L

    Accessories

    Accessory Cooling

    Optional accessory cooling systems

    Part No

    Description

    C1G0ºC to 40ºC**
    C2G-15ºC to 40ºC***

    Accessory Notes

    ** The cooling coil can be continuously immersed in liquids up to 100ºC with the cooler switched off and may be used to cool liquid down from 100ºC but it is not designed for continuous operation above 40ºC.
    *** Minimum operating temperature without accessory cooling is ambient +5ºC (amb.+ 15ºC for P5 and ST5 tanks).

    Bridge Plates

    For use with stainless steel and plastic tanks

    Part No

    Description

    G-BTSBridge plate fits G Optima heating circulator models to ST5 tank
    G-BTLBridge plate fits G Optima heating circulator models to ST12, 18, 26 & 38 tanks
    G-BSSBridge plate fits G Optima heating circulator models to S5 tanks
    G-BSLBridge plate fits G Optima heating circulator models to S12, 18, 26, 38 tanks
    T-BTSBridge plate replacement fits T Optima heating circulator models to ST5 tank
    T-BTLBridge plate replacement fits T Optima heating circulator models to ST12, 18, 26 & 38 tanks
    T-BSSBridge plate fits T Optima heating circulator models to S5 tank
    T-BSLBridge plate fits T Optima heating circulator models to S12, 18, 26 & 38 tanks
    T-BYWSBridge plate fits T Optima heating circulator models to Y6 & W6 tanks
    T-BYWLBridge plate fits T Optima heating circulator models to Y14, 28 & 38 tanks also W14, 28 & 38 tanks
    G-BPSBridge plate fits G Optima heating circulator models to P5 tank
    G-BPLBridge plate fits G Optima heating circulator models to P12 & 18
    T-BPSBridge plate replacement fits T Optima heating circulator models to P5 tank
    T-BPLBridge plate replacement fits T Optima heating circulator models to P12 & 18 tanks

     

    Clamp

    To attach heating circulators to any vertical sided tank

    Part No

    Description

    T-CLAMPAllows heating circulator to be attached to virtually any vertical sided vessel with a maximum wall thickness of 35mm for rectangular tanks, 30mm for circular tanks (300mm diameter), and capacity up to 50L

    Heated Circulating Bath – Lids

    To help reduce evaporation / heat loss and avoid sample contamination*

    Part No

    Description

    STL5Flat stainless steel lid for 5L bath
    STL12Gabled, hinged (removable) stainless steel lid for 12L bath
    STL26Gabled, hinged (removable) stainless steel lid for 18L and 26L bath
    STL38Gabled, hinged (removable) stainless steel lid for 38L bath
    PL5Flat, stainless steel lid for 5L bath
    PL12Curved plastic lid for 12L bath
    PL18Curved plastic lid for 18L bath

    Accessory Notes

    * Between operating temperatures 60ºC and 100ºC and below room temperature a lid or layer of polypropylene spheres should be used.

    Heated Circulating Bath – Racks

    To optimise available bath capacity.

    Part No

    Tube size

    Capacity

    VR-13Ø10-13 mm65
    VR-19Ø16-19 mm36
    VR-24Ø24 mm23
    VR-30Ø30 mm14
    VR-SE0.5 ml102
    VR-LE1.5ml75
    QR-13Ø10-13 mm30
    QR-19Ø16-19 mm16
    QR-24Ø24 mm10
    QR-30Ø30 mm5
    QR-SE0.5 ml44
    QR-LE1.5 ml35

    Accessory Notes

    Number of racks accommodated in stainless steel / plastic baths:

    5 litres: 1 x QR
    12 litres: 2 x VR
    18 litres: 4 x VR
    26 litres: 4 x VR
    38 litres: 6 x VR

    Polypropylene Spheres

    Ideal alternative to a lid*

    Part No

    Description

    Packs per bath

    PS-20Pack of 300 polypropylene spheres1 x 5/12L, 2 x 18/26L, 3 x 38L

    Accessory Notes

    * Between operating temperatures 60ºC and 100ºC and below room temperature a lid or layer of polypropylene spheres should be used.

    Pump Connectors

    Optional

    Part No

    Description

    P-M6Replacement plastic pump inlet/outlet connector. Fits tubing 9mm inner dia. Temperature range -50 to 200ºC
    P-M11Replacement plastic pump inlet/outlet connector. Fits tubing 15mm inner dia. Temperature range -50 to 200ºC
    M-SR4Metal pump inlet/outlet connector, dual seal super rapid 4mm. Fits semi rigid tubing 4mm outer dia. Temperature range -20 to 100ºC
    M-SR6Metal pump inlet/outlet connector, dual seal super rapid 6mm. Fits semi rigid tubing 6mm outer dia. Temperature range -20 to 100ºC
    M-SR8Metal pump inlet/outlet connector, dual seal super rapid 8mm. Fits semi rigid tubing 8mm outer dia. Temperature range -20 to 100ºC
    M-HB7Metal pump inlet/outlet connector, hose barb 7mm. Fits flexible tubing 7mm inner dia. Temperature range -40 to 120ºC
    M-HB9Metal pump inlet/outlet connector, hose barb 9mm. Fits flexible tubing 9mm inner dia. Temperature range -40 to 120ºC
    M-HB12Metal pump inlet/outlet connector, hose barb 12mm. Fits flexible tubing 12mm inner dia. Temperature range -40 to 120ºC
    M-UCMetal pump inlet/outlet plate, 1/4‘‘ BSP/G1/4 female. Temperature range -50 to 200ºC

    Raised Shelves

    To allow accommodation of shallow vessels

    Part No

    Description

    RS14For 12L bath
    RS22For 18L bath
    RS28For 26L or 38L bath
    RS38For 38L bath

    Vertical Turbine Pump

    Low noise, compact design. Supplied with pipe connections and special lid for fitting to tanks, pipe bore 12.7mm.

    Part No

    Description

    VTP1-LTMaximum pressure 1000 mbar, Maximum flow 9 L/min
    VTP2-LTMaximum pressure 1650 mbar, Maximum flow 12 L/min

    Accessory Notes

    Required only where application demands a higher pressure than that delivered by the internal pump to maintain flow.