TXF200 Series Heated Circulating Baths

Product Calibration

A product calibration service is available which includes a calibration certificate, traceable to national standards.  Please enquire prior to placing order. 

Labwise™ PC software (optional)
 General purpose digitalAdvanced digital
T100TC120TX150TXF200
Allows two-way communication for status display, programming and data capture. USB/RS232 provided - - YES YES
External probes (optional)
 General purpose digitalAdvanced digital
T100TC120TX150TXF200
for monitoring and controlling temperature of remote loads  
TXPEP flexible plastic probe, 3 m cable - - YES YES
TXSEP stainless steel probe, 3 m cable - -
Remote switching device (optional)
 General purpose digitalAdvanced digital
T100TC120TX150TXF200
For switching appliances on and off (up to max. 8 Amps) - - 1 1
Vertical turbine pumps (optional)*
 General purpose digitalAdvanced digital
T100TX120TX150TXF200
Low noise, compact design. Supplied with pipe connections and special lid for fitting to tanks, pipe bore 12.7 mm   Required only where application demands a higher pressure than that delivered by the internal pump to maintain flow
VTP 1 YES
max. pressure 1000 mbar
max. flow 9 L/min
VTP 2 YES
max. pressure 1650 mbar
max. flow 12 L/min
* When pump is fitted, available working area is reduced.
** Maximum depth can be increased by 10 mm, by removing the circulation tray in 18, 26 and 38 litre baths, with slight loss of performance.
High pressure pumps (optional)
 VTP Pumps
VTP1VTP2
Maximum pressure water mbar 1000 1650
Maximum flow water L/min 9 12
Pipe bore inlet/outlet mm 12.7 12.7
Electrical connection     10 amp IEC 10 amp IEC
Power consumption   W 30 40
Power output to liquid @ 20°C   W 15* 22*
Safety     thermal fuse thermal fuse

* The VTP optional pumps will transfer additional heat to the baths, so the minimum temperature achievable with or without accessory cooling will be increased.
Note: When ordering a VTP pump, please specify which Grant tank is to be used with.

Accessories
Lids*
to help reduce evaporation/heat loss and avoid sample contamination

Lids 
for continuous use with water above 90°C. Stainless steel

Polypropylene spheres* (no. of packs required) Rack systems†
to optimise use of available bath capacity (no. of racks accommodated)
Raised shelves
to allow shallow vessels to be accommodated
Accessory cooling systems**
to allow systems to operate at or below ambient temperature by means of a cooling coil dipped into the bath; designed for minimal impact on working area
Refrigerated immersion coolers Consist of a cooling coil connected to a refrigerated unit by a flexible pipe. Extract heat continuously, with the bath control unit controlling temperature Heat exchange coil Designed to be attached to a supply of cooling tap water or a refrigerated circulator

C1G
(0 to 40°C***)

C2G
(- 15 to 40°C***)

CW5
(2°C above coolant temperature)

STL5 flat stainless steel  - 1 x PS20 1 x QR - YES - YES
STL12 gabled, hinged (removable) stainless steel

LST12

1 x PS20 2 x VR RS14 YES - YES
STL26 for ST18 tank gabled, hinged (removable) stainless steel LST26 2 x PS20 4 x VR RS22 YES - YES

STL26 for ST26 tank  gabled, hinged (removable) stainless steel

LST26

2 x PS20 4 x VR RS28 YES YES YES
STL38 gabled, hinged (removable) stainless steel LST38 3 x PS20 6 x VR RS28 or RS38 YES YES YES
PL5 flat, stainless steel  - 1 x PS20 1 x QR - - - -
PL12 curved plastic  - 1 x PS20 2 x VR RS14 - - -
PL18 curved plastic  - 2 x PS20 4 x VR RS22 - - -
* Between operating temperatures 60°C and 100°C and below room temperature a lid or layer of polypropylene spheres should be used.
** The cooling coil can be continuously immersed in liquids up to 100°C with the cooler switched off, and may be used to cool liquid down from 100°C, but it is not designed for continuous operation above 40°C.
*** Minimum operating temperature without accessory cooling is ambient + 5°C,  (amb. + 15°C for P5 tanks).
† Rack capacity (no. of test tubes per rack)
 
VR racks   Tube size Capacity   QR racks Tube size Capacity
VR-13   Ø10-13 mm 65   QR-13 Ø10-13 mm 30
VR-19   Ø16-19 mm 36   QR-19 Ø16-19 mm 16
VR-24   Ø24 mm 23   QR-24 Ø24 mm 10
VR-30   Ø30 mm 14   QR-30 Ø30 mm 5
VR-SE   0.5 ml 102   QR-SE 0.5 ml 44
VR-LE   1.5ml 75   QR-LE 1.5 ml 35
Grant accessory cooling systems
 Refrigerated immersion coolersHeat exchange coil
C1GC2GCW5
Cooling power @ 20°C W 350 400 -
  @ 0°C W 110 320 -
  @ - 10°C W - 170 -
Overall consumption   VA 300 500 -
Dimensions d/w/h mm 460/305/225 -
Weight   kg 17 21 0.1
Flexible pipe l mm 925 925 -
Coil Ø/l mm 77/55 77/55 77/55
Pipe bore inlet/outlet   mm - - 7
Electrical supply    V 120 (60 Hz) or 230 (50Hz) -
Pump Connectors
 

Part number

Replacement plastic pump inlet/outlet connector. Fits tubing 9mm inner dia. Temp range -50 to 200˚C

P-M6

Replacement plastic pump inlet/outlet connector. Fits tubing 15mm inner dia. Temp range -50 to 200˚C

P-M11

Stainless steel pump inlet/outlet connector, M16 x 1 male. Fits M16 hose. Temp range -50 to 200˚C

M-M16

Metal pump inlet/outlet connector, dual seal super rapid 4mm. Fits semi rigid tubing 4mm outer dia. Temp range -20 to 100˚C

M-SR4

Metal pump inlet/outlet connector, dual seal super rapid 6mm. Fits semi rigid tubing 6mm outer dia. Temp range -20 to 100˚C

 M-SR6

Metal pump inlet/outlet connector, dual seal super rapid 8mm. Fits semi rigid tubing 8mm outer dia. Temp range -20 to 100˚C

 M-SR8

Metal pump inlet/outlet connector, hose barb 7mm. Fits flexible tubing 7mm inner dia. Temp range -40 to 120˚C

 M-HB7

Metal pump inlet/outlet connector, hose barb 9mm. Fits flexible tubing 9mm inner dia. Temp range -40 to 120˚C

 M-HB9

Metal pump inlet/outlet connector, hose barb 12mm. Fits flexible tubing 12mm inner dia. Temp range -40 to 120˚C

 M-HB12

Metal pump inlet/outlet plate, 1/4 " BSP/G1/4 female. Temp range -50 to 200˚C

 M-UC